Message: Re: default cut value for thin absorber Not Logged In (login)
 Next-in-Thread Next-in-Thread
 Next-in-Forum Next-in-Forum

None Re: default cut value for thin absorber 

Forum: Electromagnetic Processes
Re: Question default cut value for thin absorber (Sang-jun Lee)
Date: 08 May, 2009
From: michel maire <michel maire>

On Thu, 07 May 2009 16:05:22 GMT, Sang-jun Lee wrote:
> I'm trying to simulate isotropic 60 keV gamma-lay emission inside 4pi
> gold absorber. The thickness of the gold foil is 1 X 2 um ~ 60 X 2 um.
> At first, I set the default cut value to 20 um. I just modified a
> program from my colleague, so I had no idea of proper cut value.
> Meanwhile I came to think that when the gold absorber is as thin as 20
> um or thinner than that, the cut value of 20 um might not be
> appropriate. Now I changed it into 1 um. However, I still have no idea
> of proper value for my simulation. Could you please give me some hint?
> 
> Geant4 version : 4.9.1 CLHEP version : 1.9.2.1
> 
>   defaultCutValue = 0.001*mm;
>   cutForGamma     = defaultCutValue;
>   cutForElectron  = defaultCutValue;
>   cutForPositron  = defaultCutValue;
> 
 1- gamma interactions (Compton,PhotoElec) are cut independent (in standard Em)
 2- tracking of secondary e- : it depends of what you measure (energy deposit and or particle's fluence) and the granularity of the detector.

 Let me anticipate that your results will be rather stable for any cut values of the order or below 20 um.

Inline Depth:
 1 1
 All All
Outline Depth:
 1 1
 2 2
 All All
Add message: (add)

1 Question: Re: default cut value for thin absorber   (Sang-jun Lee - 08 May, 2009)
1 Idea: Re: default cut value for thin absorber   (Vladimir Ivanchenko - 18 May, 2009)
2 None: Re: default cut value for thin absorber   (Paul Nicholas Colin Gloster - May 26, 10:35)
1 Feedback: Re: default cut value for thin absorber   (Pedro Arce - May 27, 12:12)
2 Feedback: Re: default cut value for thin absorber   (Pedro Arce - May 27, 12:13)