Message: Re: Reversing microdosimetry example Not Logged In (login)
 Next-in-Thread Next-in-Thread
 Next-in-Forum Next-in-Forum

More Re: Reversing microdosimetry example 

Forum: DNA/Very Low Energy
Re: Question Reversing microdosimetry example
Re: None Re: Reversing microdosimetry example (M. Hahn)
Date: 13 Jul, 2016
From: <anne-catherine.heuskin@unamur.be>

Hi ! Thank you, I did what you suggested. Still it doesn't work.

I used the constructor of G4EmDNAPhysics first. Then I created processes I need for my region with dummy models in the world, and set models for these processes in my region with G4EmConfigurator.

This is similar to what I did before, except that I don't handle DNA processes myself and that I don't deactivate them (anyway they wouldn't work in the metal).

As a result, I get both DNA and Livermore activated in the world (water). As if G4EmConfigurator does not care about regions...

Inline Depth:
 1 1
 All All
Outline Depth:
 1 1
 2 2
 All All
Add message: (add)

1 None: Re: Reversing microdosimetry example   (M. Hahn - 13 Jul, 2016)
(_ More: Re: Reversing microdosimetry example   (anne-catherine.heuskin@unamur.be - 13 Jul, 2016)
1 None: Re: Reversing microdosimetry example   (M. Hahn - 13 Jul, 2016)
2 None: Re: Reversing microdosimetry example   (M. Hahn - 13 Jul, 2016)
1 More: Re: Reversing microdosimetry example   (anne-catherine.heuskin@unamur.be - 14 Jul, 2016)
... 2 Message(s)
 Add Message Add Message
to: "Re: Reversing microdosimetry example"

 Subscribe Subscribe

This site runs SLAC HyperNews version 1.11-slac-98, derived from the original HyperNews