Message: How to score secondary neutron ?? Not Logged In (login)
 Next-in-Thread Next-in-Thread
 Next-in-Forum Next-in-Forum

Question How to score secondary neutron ?? 

Forum: Biasing and Scoring
Date: Sep 19, 20:16
From: Arghya Chattaraj <Arghya Chattaraj>

Hi,
  I am beginner in Geant4. I want to get number of secondary neutron due to incident proton beam (250 MeV pencil beam) on a cylindrical target. I used Multifunctional detector and neutron filter like below
  auto Detector10 = new G4MultiFunctionalDetector("dect_10");
  G4SDManager::GetSDMpointer()->AddNewDetector(Detector10);
 G4VPrimitiveScorer* primitive;
  //primitive = new G4PSTrackLength("TrackLength");
  primitive = new G4PSSphereSurfaceCurrent(psName="Current", fCurrent_In);
  //primitive = new G4PSPassageCellCurrent(psName="Current", fCurrent_In);
  primitive ->SetFilter(neutronFilter);
  Detector10->RegisterPrimitive(primitive);  
  SetSensitiveDetector("detc10LV",Detector10); 
I am getting some score but with RMS value almost 10 times higher than mean value of neutron . I used "FTFP_BERT" physics. Here I am attaching my Detectorconstuction.cc, eventaction.cc and runaction.cc

(Note: I have edited example/basic/B4d according to my requirement.)

Kindly give me some suggestion in this regards that where is the problem ? Need your expert opinion on this please.