Message: Re: Sensitive detector with G4PSCylinderSurfaceFlux Not Logged In (login)
 Next-in-Thread Next-in-Thread
 Next-in-Forum Next-in-Forum

Ok Re: Sensitive detector with G4PSCylinderSurfaceFlux 

Forum: Biasing and Scoring
Re: Question Sensitive detector with G4PSCylinderSurfaceFlux (Andrea Conti)
Re: None Re: Sensitive detector with G4PSCylinderSurfaceFlux (Tsukasa Aso)
Date: 01 Jan, 2015
From: Andrea Conti <Andrea Conti>

Tsukasa, you are right: it works ! My problem was that I order the decay of a nucleus of Ne24 one by one through the command "/run/beamOn 1" and at the first try, by chance no photons go through the detector and therefore key = 0, but val is undefined and if I let output val then it gets stuck and I have to abort the execution.

But when some photons do go through the detector, then I really get flux and I saw it calling:

G4MultiFunctionalDetector::PrintAll();

Thank you Tsukasa!

Andrea