Message: Re: Scoring Dose Not Logged In (login)
 Next-in-Thread Next-in-Thread
 Next-in-Forum Next-in-Forum

None Re: Scoring Dose 

Forum: Biasing and Scoring
Re: Question Scoring Dose (Ibrahim)
Date: 09 Dec, 2014
From: Tsukasa Aso <Tsukasa Aso>

Hi,

 The doseDeposit corrects the accumulated dose for the all events.
And, the dose in the doseDeposit is defined by the energy-deposited divided by the volume of scoring cell.

 Therefore if you are using very collimated beam, the absolute value of dose depends on the size of the volume.

  As you know, the definition of dose is rater complicated, it is valid for very small volume like a point, or for under the equilibrium condition. 
 
Best regards,